New FALCON 25-C EO SECURITY DOOR EXIT DEVICE
Fire Exit Hardware
The Falcon F-25-C Series device lets you combine the safety of a fire-rated device with the clean aesthetics that come with
a concealed vertical rod installation. In-field adjustment is simple thanks to our patented center slide mechanism. Two-point
latching ensures optimal security at the door
pecifications
Specifications:
Hand: Field reversible.
UL : A Label (3 Hr) - 8 x 10 ; 90 min. same egress - 8 x 10 .
Wood Door: 20 min. 8 x 9 ; 90 min. 8 x 8 . Consult door
manufacturer for maximum rating. Edge channel may be required.
Finishes: US3 (605); US4 (606); US10 (612); US26 (625); US26D (626);
US32 (629); US32D (630); US28 (628), 313AN.
Strikes: 4188 mortised top; 2130 flush strike bottom.
Latchbolt: Top stainless steel, 3 4 throw. Bottom bolt 1 2 throw.
Deadlocking Latchbolt: Standard in top latch.
Latch Retention Hold: Standard in top latch.
Stock Sizes: See chart.
Doors: 13 4 thick metal or wood. Specify if other than 13 4 thick.
Projection: 23 4 maximum.
Stile: 31 2 minimum. (61 2 minimum on wood doors.)
Electric Function: Can be interfaced with building security systems. Latch
retraction, FSA/FSE trim, security monitoring, electric dogging,
delayed egress and exit alarm available (EL and ED fail- secure
only). Subject to code requirements, state and local.
Fasteners: All mounting screws are concealed. All machine screws (AMS)
standard.
Sex Bolts: Required when used with wood, composite or non-reinforced
hollow metal doors. For EO device specify 6 - 425 (#10-24) SNB.
For devices with trim, specify 2 - 425 (#10-24) SNB.
ANS I: Certified ANSI A156.3-2001 Grade 1 standards.
WDC-20: Reinforcement plates supplied standard for 20-min. doors only.
F-25-C-LB R: Less bottom rod concealed vertical device. A Label (3 Hr) - 8 x 8 ;
90 min. same egress - 8 x 8.
F-25-C-WDC-LB R: Less bottom rod concealed vertical device.
Wood Door: 20 minute minimum - 8 x 8 openings. Consult door
manufacturer for maximum rating. Edge channel may be required.
Vertical Rods: Furnished to length based on 401 4 horizontal CL to finished floor
and a 7 0 door. Variations from these standards must be specified